{"id":10587,"date":"2022-10-11T09:29:55","date_gmt":"2022-10-11T08:29:55","guid":{"rendered":"https:\/\/sharep.io\/?p=10587"},"modified":"2026-09-30T06:34:36","modified_gmt":"2026-09-30T05:34:36","slug":"zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac","status":"publish","type":"post","link":"https:\/\/sharep.io\/pl\/zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac\/","title":{"rendered":"Zabezpieczenia r\u00f3\u017cnicowo pr\u0105dowe do stacji \u0142adowania \u2013 Kt\u00f3re wybra\u0107?"},"content":{"rendered":"<h1>Jakie zabezpieczenie r\u00f3\u017cnicowo-pr\u0105dowe (typu A i B) do stacji \u0142adowania wybra\u0107? RCD B, RCM B, a mo\u017ce RCD A?<\/h1>\n<p>&nbsp;<\/p>\n<h5>Bezdyskusyjnym jest, \u017ce instalacje elektryczne musz\u0105 by\u0107 odpowiednio zabezpieczone. Maj\u0105c do czynienia z wi\u0119kszymi mocami, nie mo\u017cna ryzykowa\u0107. W przypadku og\u00f3lnodost\u0119pnych stacji \u0142adowania pojazd\u00f3w elektrycznych istnieje wym\u00f3g doposa\u017cenia \u0142adowarek w zabezpieczenia r\u00f3\u017cnicowo-pr\u0105dowe (RCD, ang. Residual Current Device) typu B. Zalecamy jednak zabezpieczy\u0107 ka\u017cd\u0105 stacj\u0119 \u2013 r\u00f3wnie\u017c te do prywatnego u\u017cytku!<\/h5>\n<p>&nbsp;<\/p>\n<p>Na rynku mo\u017cemy spotka\u0107 r\u00f3\u017cne rodzaje zabezpiecze\u0144. Najwa\u017cniejsze, aby spe\u0142nia\u0142y swoj\u0105 funkcj\u0119 i by\u0142y przystosowane (ze wzgl\u0119du na moc) do stacji \u0142adowania samochod\u00f3w. W zale\u017cno\u015bci od producenta bezpiecznik\u00f3w, zaleca si\u0119 sprawdzenie poprawno\u015bci dzia\u0142ania nawet raz w miesi\u0105cu.<\/p>\n<p>Wed\u0142ug nas, <strong>ka\u017cda stacja \u0142adowania<\/strong> powinna by\u0107 zabezpieczona. Na bezpiecze\u0144stwie nie warto oszcz\u0119dza\u0107.<\/p>\n<p>Na przyk\u0142adzie stacji \u0142adowania pr\u0105dem przemiennym ShareP firmy Enelion przedstawiamy g\u0142\u00f3wne rodzaje zabezpiecze\u0144 dla wolnostoj\u0105cych \u0142adowarek s\u0142upkowych i \u0142adowarek \u015bciennych o mocy do 22 kW na punkt \u0142adowania (gniazdo).<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h4><strong>RCD A<\/strong> \u2013 zabezpieczenie przed up\u0142ywem pr\u0105du zmiennego<\/h4>\n<p>Jest to zabezpieczenie przed up\u0142ywem pr\u0105du zmiennego, zabezpieczenia typu B w niepe\u0142nej wersji.<\/p>\n<p>Sam w sobie to jedna z dw\u00f3ch cz\u0119\u015bci kompletnego bezpiecznika typu B. To najta\u0144szy (niekompletny) bezpiecznik zalecany do stacji \u0142adowania Enelion z uk\u0142adem ShareP. Mo\u017cna go zamontowa\u0107 wewn\u0105trz lub na zewn\u0105trz stacji.<\/p>\n<p>&nbsp;<\/p>\n<p>RCD A stanowi <strong>pe\u0142ne uzupe\u0142nienie zabezpieczenia<\/strong> w stacji \u0142adowania Lumina. W pozosta\u0142ych przypadkach jest niekorzystnym i niekompletnym wyborem.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h3><strong>RCM B<\/strong> \u2013 monitor up\u0142ywu pr\u0105du sta\u0142ego (and. Residual Current Monitor)<\/h3>\n<p>Jest to zabezpieczenie przed up\u0142ywem pr\u0105du sta\u0142ego, zabezpieczenia typu B w niepe\u0142nej wersji.<\/p>\n<p>Element uzupe\u0142niaj\u0105cy zapewniaj\u0105cy pe\u0142n\u0105 ochron\u0119 typu B w po\u0142\u0105czeniu z wy\u0142\u0105cznikiem r\u00f3\u017cnicowopr\u0105dowym A. Jest to (niekompletny) bezpiecznik zalecany do stacji \u0142adowania Enelion z konfiguracj\u0105 ShareP. Mo\u017cna go zamontowa\u0107 wewn\u0105trz lub na zewn\u0105trz stacji.<\/p>\n<p>RCM B stanowi pe\u0142ne uzupe\u0142nienie zabezpieczenia RCD A.<\/p>\n<p>&nbsp;<\/p>\n<p>Niekt\u00f3re stacje \u0142adowania (np. Lumina) s\u0105 ju\u017c wyposa\u017cone w RCM B. Wtedy wystarczy dokupi\u0107 RCD A. W pozosta\u0142ych przypadkach, RCM B samo w sobie jest niekorzystnym i niekompletnym wyborem.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2><strong>RCD B<\/strong> \u2013 zabezpieczenie r\u00f3\u017cnicowo-pr\u0105dowe typu A+B przed up\u0142ywem pr\u0105du sta\u0142ego oraz zmiennego<\/h2>\n<p>Jest to pe\u0142ne zabezpieczenie r\u00f3\u017cnicowo-pr\u0105dowe typu B przed up\u0142ywem pr\u0105du sta\u0142ego, jak i zmiennego.<\/p>\n<p>W zestawie znajduje si\u0119 jeden kompletny bezpiecznik. Zalecany do wszystkich rodzaj\u00f3w stacji \u0142adowania samochod\u00f3w elektrycznych. Mo\u017cna go zamontowa\u0107 wewn\u0105trz stacji (stacje Enelion z modelem ShareP) lub na zewn\u0105trz stacji, w rozdzielnicy.<\/p>\n<p>RCD B stanowi pe\u0142ne zabezpieczenie typu B i spe\u0142nia wymogi UDT w przypadku og\u00f3lnodost\u0119pnych stacji \u0142adowania.<\/p>\n<p>&nbsp;<\/p>\n<p>\u015awietnie sprawdzi si\u0119 w po\u0142\u0105czeniu m.in. z:<\/p>\n<ul>\n<li>Wallbox<\/li>\n<li>STILO<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>RCD B wystarczy aby ca\u0142kowicie zabezpieczy\u0107 stacj\u0119.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2><strong>RCD A + RCM B<\/strong> \u2013 zabezpieczenie r\u00f3\u017cnicowo-pr\u0105dowe typu B, przed up\u0142ywem pr\u0105du zmiennego i sta\u0142ego<\/h2>\n<p>Jest to pe\u0142ne zabezpieczenie r\u00f3\u017cnicowo-pr\u0105dowe RCD A (przed up\u0142ywem pr\u0105du zmiennego) i RCM B (monitor up\u0142ywu pr\u0105du sta\u0142ego), spe\u0142niaj\u0105ce w\u0142a\u015bciwo\u015bci typu B.<\/p>\n<p>Zestaw dw\u00f3ch bezpiecznik\u00f3w. Stanowi ta\u0144szy zamiennik dla modelu RCD B, pe\u0142ni\u0105c te same funkcje. Zalecany do wszystkich rodzaj\u00f3w stacji \u0142adowania samochod\u00f3w elektrycznych. Mo\u017cna go zamontowa\u0107 wewn\u0105trz (stacje Enelion z ShareP) oraz na zewn\u0105trz stacji \u0142adowania, w rozdzielnicy.<\/p>\n<p>RCD A + RCM B stanowi pe\u0142ne zabezpieczenie typu B i spe\u0142nia wymogi odbioru og\u00f3lnodost\u0119pnych stacji \u0142adowania (UDT).<\/p>\n<p>&nbsp;<\/p>\n<p>\u015awietnie sprawdzi si\u0119 w po\u0142\u0105czeniu m.in. z:<\/p>\n<ul>\n<li>Wallbox Duo Power<\/li>\n<li>VERTICA<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Zestaw RCD A i RCM B to najcz\u0119\u015bciej stosowane zabezpieczenie w stacjach \u0142adowania Enelion.<\/strong><\/p>\n<p>RCD A i RCM B wystarczy aby ca\u0142kowicie zabezpieczy\u0107 stacj\u0119.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p>Nale\u017cy pami\u0119ta\u0107, \u017ce 1 bezpiecznik przypada na 1 punkt \u0142adowania (gniazdo). Podw\u00f3jna stacja \u0142adowania musi by\u0107 wyposa\u017cona w 2 niezale\u017cne bezpieczniki (lub w podw\u00f3jny zestaw).<\/p>\n<p>&nbsp;<\/p>\n<p>Najlepszym wyborem jest:<br \/>\nZestaw RCD A i RCM B dla stacji \u0142adowania Enelion. Wyj\u0105tek stanowi stacja Lumina i bezpiecznik RCD A.<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h6>Zapraszamy do kontaktu i sprawdzenia naszej pe\u0142nej oferty.<\/h6>","protected":false},"excerpt":{"rendered":"<p>What type of residual current protection (type A and B) for charging stations should you choose? RCD B, RCM B or maybe RCD A? &nbsp; It is indisputable that electrical installations must be adequately protected. When dealing with higher wattages, no risks can be taken. In the case of public charging stations for electric vehicles, [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_eb_attr":"","inline_featured_image":false,"footnotes":""},"categories":[173],"tags":[],"class_list":["post-10587","post","type-post","status-publish","format-standard","hentry","category-curiosities"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Residual current protectors (type A and B) for charging stations - which ones to choose? - ShareP<\/title>\n<meta name=\"description\" content=\"In our opinion, every charging station should be secure. Using Enelion\u2019s ShareP AC charging station as an example, we outline the main types of protection for charging stations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sharep.io\/pl\/zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Residual current protectors (type A and B) for charging stations - which ones to choose? - ShareP\" \/>\n<meta property=\"og:description\" content=\"In our opinion, every charging station should be secure. Using Enelion\u2019s ShareP AC charging station as an example, we outline the main types of protection for charging stations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sharep.io\/pl\/zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac\/\" \/>\n<meta property=\"og:site_name\" content=\"ShareP\" \/>\n<meta property=\"article:published_time\" content=\"2022-10-11T08:29:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T05:34:36+00:00\" \/>\n<meta name=\"author\" content=\"m.wojdylo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napisane przez\" \/>\n\t<meta name=\"twitter:data1\" content=\"m.wojdylo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/\"},\"author\":{\"name\":\"m.wojdylo\",\"@id\":\"https:\\\/\\\/sharep.io\\\/#\\\/schema\\\/person\\\/5d000bcfd34261dd130723c4f3dfd27c\"},\"headline\":\"Residual current protectors (type A and B) for charging stations &#8211; which ones to choose?\",\"datePublished\":\"2022-10-11T08:29:55+00:00\",\"dateModified\":\"2026-09-30T05:34:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/\"},\"wordCount\":676,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/#organization\"},\"articleSection\":[\"Curiosities\"],\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/\",\"url\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/\",\"name\":\"Residual current protectors (type A and B) for charging stations - which ones to choose? - ShareP\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/#website\"},\"datePublished\":\"2022-10-11T08:29:55+00:00\",\"dateModified\":\"2026-09-30T05:34:36+00:00\",\"description\":\"In our opinion, every charging station should be secure. Using Enelion\u2019s ShareP AC charging station as an example, we outline the main types of protection for charging stations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/sharep.io\\\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/sharep.io\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Residual current protectors (type A and B) for charging stations &#8211; which ones to choose?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/sharep.io\\\/#website\",\"url\":\"https:\\\/\\\/sharep.io\\\/\",\"name\":\"ShareP\",\"description\":\"Sustainable Parking Management\",\"publisher\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/sharep.io\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/sharep.io\\\/#organization\",\"name\":\"ShareP\",\"url\":\"https:\\\/\\\/sharep.io\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/sharep.io\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/sharep.io\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-sharep-management.svg\",\"contentUrl\":\"https:\\\/\\\/sharep.io\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/logo-sharep-management.svg\",\"width\":\"1024\",\"height\":\"1024\",\"caption\":\"ShareP\"},\"image\":{\"@id\":\"https:\\\/\\\/sharep.io\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/stellos\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/sharep.io\\\/#\\\/schema\\\/person\\\/5d000bcfd34261dd130723c4f3dfd27c\",\"name\":\"m.wojdylo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g\",\"caption\":\"m.wojdylo\"},\"url\":\"https:\\\/\\\/sharep.io\\\/pl\\\/author\\\/m-wojdylo\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wy\u0142\u0105czniki r\u00f3\u017cnicowopr\u0105dowe (typu A i B) do stacji \u0142adowania \u2013 kt\u00f3re wybra\u0107? \u2013 ShareP","description":"Naszym zdaniem ka\u017cda stacja \u0142adowania powinna by\u0107 bezpieczna. Na przyk\u0142adzie stacji \u0142adowania pr\u0105dem przemiennym ShareP firmy Enelion przedstawiamy g\u0142\u00f3wne rodzaje zabezpiecze\u0144 stosowanych w stacjach \u0142adowania.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sharep.io\/pl\/zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac\/","og_locale":"pl_PL","og_type":"article","og_title":"Residual current protectors (type A and B) for charging stations - which ones to choose? - ShareP","og_description":"In our opinion, every charging station should be secure. Using Enelion\u2019s ShareP AC charging station as an example, we outline the main types of protection for charging stations.","og_url":"https:\/\/sharep.io\/pl\/zabezpieczenia-roznicowopradowe-typu-a-i-b-do-stacji-ladowania-ktore-wybrac\/","og_site_name":"ShareP","article_published_time":"2022-10-11T08:29:55+00:00","article_modified_time":"2026-09-30T05:34:36+00:00","author":"m.wojdylo","twitter_card":"summary_large_image","twitter_misc":{"Napisane przez":"m.wojdylo","Szacowany czas czytania":"3 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/#article","isPartOf":{"@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/"},"author":{"name":"m.wojdylo","@id":"https:\/\/sharep.io\/#\/schema\/person\/5d000bcfd34261dd130723c4f3dfd27c"},"headline":"Residual current protectors (type A and B) for charging stations &#8211; which ones to choose?","datePublished":"2022-10-11T08:29:55+00:00","dateModified":"2026-09-30T05:34:36+00:00","mainEntityOfPage":{"@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/"},"wordCount":676,"commentCount":0,"publisher":{"@id":"https:\/\/sharep.io\/#organization"},"articleSection":["Curiosities"],"inLanguage":"pl-PL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/","url":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/","name":"Wy\u0142\u0105czniki r\u00f3\u017cnicowopr\u0105dowe (typu A i B) do stacji \u0142adowania \u2013 kt\u00f3re wybra\u0107? \u2013 ShareP","isPartOf":{"@id":"https:\/\/sharep.io\/#website"},"datePublished":"2022-10-11T08:29:55+00:00","dateModified":"2026-09-30T05:34:36+00:00","description":"Naszym zdaniem ka\u017cda stacja \u0142adowania powinna by\u0107 bezpieczna. Na przyk\u0142adzie stacji \u0142adowania pr\u0105dem przemiennym ShareP firmy Enelion przedstawiamy g\u0142\u00f3wne rodzaje zabezpiecze\u0144 stosowanych w stacjach \u0142adowania.","breadcrumb":{"@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sharep.io\/residual-current-protectors-type-a-and-b-for-charging-stations-which-ones-to-choose\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sharep.io\/"},{"@type":"ListItem","position":2,"name":"Residual current protectors (type A and B) for charging stations &#8211; which ones to choose?"}]},{"@type":"WebSite","@id":"https:\/\/sharep.io\/#website","url":"https:\/\/sharep.io\/","name":"ShareP","description":"Zr\u00f3wnowa\u017cone zarz\u0105dzanie parkingami","publisher":{"@id":"https:\/\/sharep.io\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sharep.io\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/sharep.io\/#organization","name":"ShareP","url":"https:\/\/sharep.io\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/sharep.io\/#\/schema\/logo\/image\/","url":"https:\/\/sharep.io\/wp-content\/uploads\/2026\/03\/logo-sharep-management.svg","contentUrl":"https:\/\/sharep.io\/wp-content\/uploads\/2026\/03\/logo-sharep-management.svg","width":"1024","height":"1024","caption":"ShareP"},"image":{"@id":"https:\/\/sharep.io\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/stellos"]},{"@type":"Person","@id":"https:\/\/sharep.io\/#\/schema\/person\/5d000bcfd34261dd130723c4f3dfd27c","name":"m.wojdylo","image":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/secure.gravatar.com\/avatar\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/106c1c29b42e6e448121b4e207a679d5716df894fa1e8cc16b259ca41c896608?s=96&d=mm&r=g","caption":"m.wojdylo"},"url":"https:\/\/sharep.io\/pl\/author\/m-wojdylo\/"}]}},"_links":{"self":[{"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/posts\/10587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/comments?post=10587"}],"version-history":[{"count":5,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/posts\/10587\/revisions"}],"predecessor-version":[{"id":24618,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/posts\/10587\/revisions\/24618"}],"wp:attachment":[{"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/media?parent=10587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/categories?post=10587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sharep.io\/pl\/wp-json\/wp\/v2\/tags?post=10587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}